Hurricane Rib™

Features


Developed as an economical profile for use in known cyclonic zones. High level of rigidity and good structural performance. 1.5 corrugation sidelap.

Applications

May be specified as single skin, thermally or acoustically rated roof and/or wall cladding.

Applications have included structures for defence and aviation in cyclonic regions.

Orientation & Accessories

Can be installed as a vertical, horizontal or diagonal system to walls. Supplied with a range of accessories as required.

 

 

 

 

 

 

Roof Load Span Data

Allowable Safe Load Table (values in kPa)

Span mm Single Span

Double span

Triple span
  Base steel thickness
  0.6 0.7 0.9 0.6 0.7 0.9 0.6 0.7 0.9
900 14.16* 17.12* 22.41* 14.16* 17.12* 22.41* 17.70* 21.41* 28.01*
1200 7.64 9.20 12.09* 7.97* 9.63* 12.60* 9.96* 12.04* 15.76*
1500 3.91 4.71 6.19 5.10* 6.16* 8.07* 6.37* 7.71* 10.08*
1800 2.26 2.72 3.58 3.54* 4.28* 5.60* 4.27 5.14 6.76
2100 1.43 1.72 2.26 2.60* 3.15* 4.12* 2.69 3.24 4.26
2400 n/r 1.15 1.51 1.99* 2.41* 3.15* 1.80 2.17 2.85
2700 n/r n/r 1.06 1.57* 1.90* 2.49* 1.27 1.52 2.00
3000 n/r n/r n/r n/r 1.42* 1.86 n/r 1.11 1.46
3300 n/r n/r n/r n/r n/r 1.40 n/r n/r 1.10

Notes: Allowable loads limited by stress of 180 MPa, or deflection of L/180.
* Denotes where values determined by stress. n/r Not Recommended.

Table of Properties

Base steel thickness mm Mass per unit length * kg/m Mass per unit area * kg/m2 Stress coefficients Deflection coefficients
Single span Double span Triple span Single span Double span Triple span
0.6 5.20 6.58 11.47 11.47 14.34 13.20 31.74 24.91
0.7 5.91 7.48 13.87 13.87 17.34 15.89 38.21 29.99
0.9 7.32 9.26 18.15 18.15 22.69 20.89 50.20 39.41

Notes: To obtain maximum allowable loads in kPa for spans not listed, divide coefficient of stress by the square of the span in metres. Divide coefficient of deflection by the cube of span in metres.
* Denotes mass of Hot Metal Versacor material. Other finishes marginally lower.

 

 

Roof Cladding
790mm cover width roof cladding.
Profile depth 35mm.

Exposed Fastener: Hurricane Rib Roof

Fastening Details

(For non-cyclonic and non-typhoon areas)

Wall Load Span Data

Allowable Safe Load Table (values in kPa)

Span mm Single Span

Double span

Triple span
  Base steel thickness
  0.6 0.7 0.9 0.6 0.7 0.9 0.6 0.7 0.9
900 18.88* 22.83* 29.88* 18.88* 22.83* 29.88* 23.60* 28.54* 37.35*
1200 10.62* 12.84* 16.81* 10.62* 12.84* 16.81* 13.28* 16.06* 21.01*
1500 5.87 7.06 9.28 6.80* 8.22* 10.76* 8.50* 10.28* 13.44*
1800 3.40 4.09 5.37 4.72* 5.71* 7.47* 5.90* 7.14* 9.34*
2100 2.14 2.57 3.38 3.47* 4.19* 5.49* 4.03* 4.86 6.38
2400 1.43 1.72 2.27 2.65* 3.21* 4.20* 2.70 3.25 4.28
2700 1.01 1.21 1.59 2.10* 2.54* 3.32* 1.90 2.29 3.00
3000 0.73 0.88 1.16 1.70* 2.05* 2.69* 1.38 1.67 2.19
3300 0.55 0.66 0.87 1.32 1.60 2.10 1.04 1.25 1.64

Notes: Allowable loads limited by stress of 240 MPa, or deflection of L/120.
* Denotes where values determined by stress.

Table of Properties

Base steel thickness mm Mass per unit length * kg/m Mass per unit area * kg/m2 Stress coefficients Deflection coefficients
Single span Double span Triple span Single span Double span Triple span
0.6 5.20 6.58 15.29 15.29 19.12 19.80 47.60 37.36
0.7 5.91 7.48 18.49 18.49 23.12 23.84 57.32 44.99
0.9 7.32 9.26 24.20 24.20 30.25 31.33 75.31 59.11

Notes: To obtain maximum allowable loads in kPa for spans not listed, divide coefficient of stress by the square of the span in metres. Divide coefficient of deflection by the cube of span in metres.
* Denotes mass of Hot Metal Versacor material. Other finishes marginally lower.

 

 

 

Wall Cladding
948mm cover width wall cladding.
Profile depth 35mm.

Exposed Fastener: Hurricane Rib Wall

Fastening Details

(For non-cyclonic and non-typhoon areas)